- 90A switching capability
- Very minimal power consumption from the coil
- 9mm creepage distance
- 4KV dielectrics strength coil to contact
- In accordance with IEC62055-31:UC2
- Outline dimensions:(36*30*16.5)mm
- CE,CQC compliant
- RoHS,UL compliant
Home / Products / Magnetic Latching Relay / 90A Magnetic Latching Relay for synchronous switch

|
Contact Data
|
|
| Rated load(FLA) | 90A/250VAC |
| Contact form | 1A & 1B |
| Contact material | AgSnO₂ |
| Initial contact resistance | ≤2mΩ(0.1A@6vdc) |
| Max.switching current | 90A |
| Max.switching voltage | 250VAC |
| Max.switching power | 22,500VA |
| Electical endurance | 1x104ops |
| Mechanical endurance | 1x106ops |
|
Coil Powera
|
||
| Coil type | Pulse duration | Power consumption |
| Single | Min.50ms | 1.5W |
| Dual | Min.50ms | 3.0W |
|
Characteristics
|
|
| Insulation resistance | 1,000MΩ(at 500VDC) |
| Dielectric strength | |
| Coil to contact | 4,000VAC 1 min |
| Across open contact | 1,800VAC 1 min |
| Operate time | Max.20ms |
| Release time | Max.20ms |
| Shoock resistance functional | 100m/s²(10g) |
| Shoock resistance destructive | 1000m/s²(100g) |
| Ambient temperature | -40 ~ 70℃ |
| Humidity | 98%RH,+40℃ |
| Vibration resistance | 10-55HZ,1.5mm(DA) |
| Termination | PCB |
| Unit weight | 40g |
| Construction | Dust protected |
|
Coil Data
|
|||
| Nominal coil voltage | Min.operating voltage | Max.operating voltage | Coil Resistance (Ω±10%)@23℃ |
| Single coil resistance | Dual coil resistance | ||
| 6Vdc | 4.5Vdc | 12Vdc | 24Ω |
| 9Vdc | 6.3Vdc | 18Vdc | 54Ω |
| 12Vdc | 8.4Vdc | 24Vdc | 96Ω |
| 24Vdc | 16.8Vdc | 48Vdc | 384Ω |
|
Order Information
|
|
| Terminal Type | See drawing |
| Custom design | |
| Coil Type | Single coil latching |
| Dual coil latching | |
| Coil Voltage | 6,9,12,24Vdc |
| Coil Polarity | Positive |
| Negative | |

Vertical installation of exterior dimensions(mm)

Install exterior horizontal dimensions(mm)

| Contact A | Contact B |
![]() |
![]() |
1、All relays are shipped in the “closed”position.It is possible that during transit or final assembly the relay could change its state to the “open”position.
Therefore,it is recommended that all relays be set to the desired state of the relay via a power supply.
2、In order to maintain an “open” or “closed” state of the relay,the coil voltage should reach the rated voltage. The pulse width should be 5 times the
operating time to ensure a proper change of state.Do not energize both T1 and T2 at the same time on a dual coil or energize the coil for longer than 1 minute
(damage to the coil could incur).
3、Relays have polarity,if the user’s need different from information,shoud be contact us.
4、The relay to the factory inspection and use should handle to prevent damage effect,to the factory for damaging the goods shoud be strict distinction between
the normal product and must not uses.